CBQBL - CUSTOM INORGANIC MIX, IS-2818B

  • MSDS: CBQBL
  • Manufacturer: ACCUSTANDARD INC
  • Product Name: CUSTOM INORGANIC MIX, IS-2818B
  • National Stock Number: 6630-00N072201
Product Identification

Product ID:CUSTOM INORGANIC MIX, IS-2818B
MSDS Date:03/13/1995
FSC:6630
NIIN:00N072201
Kit Part:Y
MSDS Number: CBQBL

Responsible Party
ACCUSTANDARD INC
25 SCIENCE PARK SUITE 687
NEW HAVEN, CT 06511
US

Emergency Phone: 203-786-5290

Info Phone: 203-786-5290

Cage: 0U4A8

Contractor
ACCUSTANDARD INC
NEW HAVEN, CT 06513 US

Telephone: 800-442-5290

Cage: 0U4A8

Ingredients

NITRIC ACID (SARA 302/313) (CERCLA)

CAS: 7697-37-2

RTECS: QU5775000

Fraction By Weight: 5-10%

OSHA PEL 2 PPM

ACGIH TLV: 2 PPM; 4 STEL

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


WATER

CAS: 7732-18-5

RTECS: ZC0110000

Fraction By Weight: 94%

OSHA PEL N/K

ACGIH TLV: N/K


9); (AL AS

CAS: 7784-27-2

RTECS: BD1050000

Fraction By Weight: 0.1%

OSHA PEL N/K

ACGIH TLV: 2 MG/M3


COPPER (SARA 313) (CERCLA)

CAS: 7440-50-8

RTECS: GL5325000

Fraction By Weight: 0.10%

OSHA PEL 0.1MG/M3 FUME;1 DUST

ACGIH TLV: 0.2 MG/M3 FUME

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


IRON

CAS: 7439-89-6

RTECS: NO4565500

Fraction By Weight: 0.1%

OSHA PEL N/K

ACGIH TLV: N/K


NICKEL (SARA 313) (CERCLA)

CAS: 7440-02-0

RTECS: QR5950000

Fraction By Weight: 0.1-1%

OSHA PEL 1 MG/M3

ACGIH TLV: 1 MG/M3

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:IRRITATING TO EYES AND MUCOUS
MEMBRANES. MAY CAUSE EYE INJURY. MAY BE HARMFUL IF SWALLOWED. MAY
BE IRRITATING ON CONTACT WITH SKIN, EYES OR MUCOUS MEMBRANES. VAPOR
IRRITATING TO EYES AND RESPIRATORY P ASSAGES.
Explanation of Carcinogenicity:NICKEL: IARC MONOGRAPHS ON THE EVAL OF
CARCIN RISK OF CHEMS TO MAN, VOL 49, PG 257, 1990:GROUP 2B. NTP 7TH
(SUPDAT)
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:RESPIRATORY CONDITIONS.

First Aid

First Aid:GET MEDICAL ASSISTANCE FOR ALL CASES OF OVEREXPOSURE. SKIN:
IMMEDIATELY FLUSH THOROUGHLY WITH LARGE AMOUNTS OF WATER. EYES:
IMMEDIATELY FLUSH THOROUGHLY WITH WATER FOR AT LEAST 15 MINUTES.
INHAL: REMO VE TO FRESH AIR; GIVE ARTIFICIAL RESPIRATION IF
BREATHING HAS STOPPED. INGEST: GET IMMEDIATE MEDICAL ATTENTION; IF
CONSCIOUS, GIVE WATER FREELY.

Fire Fighting

Flash Point:NONCOMBUSTIBLE
Extinguishing Media:USE ANY SUITABLE FOR ADJACENT MATERIAL.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:THERMAL DECOMPOSITION PRODUCES TOXIC
FUMES.

Accidental Release

Spill Release Procedures:EVACUATE AREA OF ALL UNNEC PERS. WEAR SUITABLE
PROT EQUIP AS LISTED. ELIM ANY IGNIT SOURCES UNTIL AREA IS DETERMD
TO BE FREE FROM EXPLO/FIRE HAZS. CNTN RELS & ELIM ITS SOURCE IF IT
CAN BE DONE W/OUT R ISK. TAKE UP & CONTAINERIZE FOR PROPER
DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:KEEP CONTAINER CLOSED. STORE AT
CONTROLLED ROOM TEMPERATURE.
Other Precautions:DO NOT BREATHE VAPOR. DO NOT GET IN EYES, ON SKIN OR
ON CLOTHING.

Exposure Controls

Respiratory Protection:USE NIOSH APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:MATERIAL SHOULD BE HANDLED OR TRANSFERRED IN AN APPROVED
FUME HOOD OR WITH ADEQUATE VENTILATION.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPROVED EYE WASH & DELUGE SHOWER .
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING. DO NOT TAKE
INTERNALLY.
Supplemental Safety and Health
EXPLAN OF CARCIN: ANNUAL REPORT ON CARCINS, 1994:ANTIC TO BE CARCIN.
HUMAN:LUNGS, NASAL CAVITIES.

Chemical Properties

Solubility in Water:SOLUBLE
Appearance and Odor:LIQUID.

Stability

Stability Indicator/Materials to Avoid:YES
NONE INDICATED.
Stability Condition to Avoid:EXTREME HEAT.
Hazardous Decomposition Products:OXIDES OF NITROGEN.

Disposal

Waste Disposal Methods:COMPLY WITH WITH FEDERAL, STATE AND LOCAL
REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.